• Red Rainbow Tech SpO2 Sensor sekali pakai 1859 2317 LNCS Adtx Rad-57 Radical-7
  • Red Rainbow Tech SpO2 Sensor sekali pakai 1859 2317 LNCS Adtx Rad-57 Radical-7
  • Red Rainbow Tech SpO2 Sensor sekali pakai 1859 2317 LNCS Adtx Rad-57 Radical-7
  • Red Rainbow Tech SpO2 Sensor sekali pakai 1859 2317 LNCS Adtx Rad-57 Radical-7
  • Red Rainbow Tech SpO2 Sensor sekali pakai 1859 2317 LNCS Adtx Rad-57 Radical-7
Red Rainbow Tech SpO2 Sensor sekali pakai 1859 2317 LNCS Adtx Rad-57 Radical-7

Red Rainbow Tech SpO2 Sensor sekali pakai 1859 2317 LNCS Adtx Rad-57 Radical-7

Detail produk:

Tempat asal: Cina
Nama merek: BESTMED& OEM
Sertifikasi: ISO13485& DOC
Nomor model: BSAY01-18

Syarat-syarat pembayaran & pengiriman:

Kuantitas min Order: 25pcs
Harga: depends on quantity & negotiation
Kemasan rincian: 1 pcs per tas kemudian 50 pcs ke dalam tas PE besar atau paket sesuai kebutuhan pelanggan
Syarat-syarat pembayaran: Serikat Barat, MoneyGram, L/C, T/T
Menyediakan kemampuan: 50000 pcs per bulan
Harga terbaik Kontak

Informasi Detail

Properti: Aksesoris Medis Jenis: persediaan bedah
Klasifikasi Instrumen: Kelas II Warna: Hitam
Konektor: DB9 9Pin Kompatibel untuk: untuk M-asi-mo Pronto-7, Rad-5, Rad-57, Rad-8, Rad-87, Radical-7
teknologi: untuk M-asi-mo Red tech Rainbow tech sabar: dewasa / Neonatus / anak / bayi
Bahan: kain bukan tenunan Panjang: 85CM
Menyoroti:

Red Rainbow teknologi SpO2 sensor sekali pakai

,

LNCS Adtx Sensor SpO2 sekali pakai

,

Sensor sekali pakai Radical-7

Deskripsi Produk

1. Nama produk

untuk M-asi-mo Red Rainbow tech 1859 2317 LNCS Adtx Sensor SpO2 sekali pakai Rad-57 Radical-7 Kain non tenunan

2. Fitur Sensor Spo2 sekali pakai

Sensor Adhesive Pulse Oximeter for M-asi-mo adalah probe sekali pakai untuk neonatal/ bayi/ anak/ orang dewasa untuk digunakan pada satu pasien saja.
Untuk digunakan dengan M-asi-mo Red tech Pronto-7, Rad-5, Rad-57, Rad-8, Rad-87, Radical-7 untuk menyediakan pemantauan saturasi oksigen (SpO2) non- invasif untuk pasien dewasa, pediatrik, bayi dan neonatal.
Hal ini ditunjukkan untuk bayi baru lahir hingga 3 kg, bayi di atas 3 kg dan di bawah 5 kg, anak-anak di atas 5 kg dan di bawah 40 kg atau orang dewasa di atas 40 kg.

3. Parameter teknis

Keakuratan SpO2 Rentang (80%-100%) Keakuratan ± 2%
Jangkauan (70%-89%) Keakuratan ± 3%
Jangkauan (< 69%) Tidak ditentukan
Pulsa 20-250 bpm Keakuratan ± 3 digit

4Nomor Bagian OEM Referensi silang:

Produsen

Bagian OEM #

Draeger

MP00790

GE Healthcare > Marquette

2027253-001

untuk M-asi-mo

1859 LNCS Adtx (18"), 2317 (LNCS Adtx-3)

Mindray > Datascope

0600-00-0121, 520A-30-64101

P-hilips

989803148231

Stryker > Med-tronic > Physio Control

11171-000019

Zoll

8000-0320

5Kompatibilitas:

Produsen

Model

Bitmos

sat 800, sat 801, sat 805, sat 816, satPuls

Datex Ohmeda

Pemanas Bayi Jerapah, S/5

Draeger

Infinity Delta, Infinity Delta XL, Infinity Kappa, Infinity M540, Narkomed 6400

GE Healthcare > Korometri

128, 250, 250cx, TRAM 450SL

GE Healthcare > Critikon > Dinamap

Carescape B650, Carescape B850, Carescape V100, Carescape V100 dengan teknologi M-asi-mo, Dinamap ProCare dengan M-asi-mo Pro 1000, Pro 300V2, ProCare 300, ProCare Ausculatory 400, ProSeries V2,V300

GE Healthcare > Marquette

8000 e Eagle 1000, Dash 2000, Dash 2500, Dash 3000, Dash 4000, Dash 5000, Seri Dash, Eagle, Modul PDM, Procare B40, SOLAR, Smk SMV, Solar 7000, Solar 8000, Solar 8000M, Seri Solar, TRAM Modular,Trem 451, i/9500, i/9500 (Tram 451N5/851N5), Seri x50SL

Invivo

Pengiring II OPT30 Prisma, T8

untuk M-asi-mo

Semua, Pronto-7, Rad-5, Rad-57, Rad-8, Rad-87, Radikal-7

Pria

Horizon XVu

Mindray > Datascope

Accutor V, Accutorr 3, Accutorr 7, Accutorr Plus, Accutorr V, BeneView T1, BeneView T5, BeneView T8, BeneVision TMS60, BeneVision TMS80, Beneheart D6, DPM4, DPM6, DPM7, Duo, EPM4, MEC 12, MPM,PM 6000, PM 6800, PM 7000, PM 8000, PM 9000, Passport 12, Passport 2, Passport 2LT, Passport 8, Passport V, Passport XG, Spektrum, Spektrum OR, Trio, V12, V21, VS 800, cPM 12, cPM 8, ePM 10M, ePM 12M,IPM-9800

Penlon InterMed

Semua

P-hilips

Heartstream XL, IntelliVue FAST-SpO2, IntelliVue MP70, M1020B, M2601A, M3000A, M3001A, M3001A A03, M3001A A03C06, M3001A A03C12, M3001A A03C18, M3002A, M3002A MMS X2, M3500B, M4735A, M8102A,M8102A MP2, M8105A MP5, M8105AS, MP 30, SureSigns VS2, SureSigns VS3, VM4

Respironik

Alice 5

Stryker > Med-tronic > Physio Control

Lifepak 11, Lifepak 12, Lifepak 15, Lifepak 20, Lifepak 20E

Welch Allyn

1500, 45NE0-E1 LX, 53S00, 53S0P, 53ST0, 53STP, Propaq CS, Propaq LT, Spot Vital Signs

Zoll

Seri E, Seri M, Seri R, Seri X

6. Model lainnya:

REF

Deskripsi Sensor

BSAY01-18

DB9 9Pin Kain Nonwoven Dewasa

BSAY02-18

DB9 9Pin Peidatric Nonwoven Fabric

BSAY03-18

DB9 Kain Non-Woven 9Pin untuk Bayi

BSAY04-18

DB9 9Pin Kain Non-Woven Dewasa/Neoante

BSAY05-18

DB9 9Pin Kain Peregangan Kulit Dewasa

BSAY06-18

DB9 9Pin Pedatric Skin Stretch Fabric

BSAY07-18

DB9 9Pin Kain Peregangan Kulit Bayi

BSAY08-18

DB9 9Pin Adult/Neonatal Skin Stretch Fabric

BSAY09-18

DB9 9Pin Dewasa/Neoante Blue Spong

BSAY10-18

DB9 8Pin Pediatric/Infant Blue Spong

BSAY11-18

DB9 8Pin kulit dewasa White Foam

BSAY12-18

DB9 9Pin Kulit Anak Putih busa

BSAY13-18

DB9 9Pin Kulit Bayi Bubuk Putih

BSAY14-18

DB9 9Pin Bubuk Putih Dewasa/Neonatal

7. Produk Perusahaan:

Sensor SpO2 yang dapat digunakan kembali

Sensor SpO2 sekali pakai

Kabel adaptor SpO2

Kabel EKG dan kabel timah

Kabel EKG dan Kabel Utama

Kabel EKG Holter dan Leadwires

Kabel ECG Trunk 3/5/10 Lead

ECG Leadwires 3/5/10Lead

Elektrod EKG dan Aksesoris EKG/EKG

Kabel EKG radiatranparent dan leadwires

Probe suhu dan kabel adaptor

Kabel dan adaptor IBP Kabel dan transduser IBP sekali pakai

NIBP Cuff dan NIBP Adapter Hose Tube

Elektroda EEG Kabel Timah

Suku cadang dan kabel semi-sink

Red Rainbow Tech SpO2 Sensor sekali pakai 1859 2317 LNCS Adtx Rad-57 Radical-7 0

8. Sertifikat

Red Rainbow Tech SpO2 Sensor sekali pakai 1859 2317 LNCS Adtx Rad-57 Radical-7 1

9. FAQ

T: Apakah Anda perusahaan dagang atau produsen?
A: Kami adalah produsen asli. Kami dapat melakukan bisnis OEM / ODM.

T: Berapa lama waktu pengiriman Anda?
A: Pemesanan stok: 1-2 hari
Orde normal 2-4 hari
Batch order tergantung pada produksi & jumlah pesanan dan negosiasi.


T: Apa syarat pembayaran dan cara pembayaran Anda?
A: 100% pembayaran di muka. Pembayaran dengan TT / Western Union / Paypal / / Ali pay / Wechat / L / C ((beberapa negara) dapat diterima.


T: Bagaimana cara membeli produk Anda?
A: Anda dapat membeli produk dari perusahaan kami secara langsung. Biasanya prosedurnya adalah menandatangani kontrak, melakukan pembayaran, hubungi kurir untuk mengirimkan barang.

T: Apa cara pengiriman?
A: 1. Kami mengirimkan barang dengan DHL/Fedex/UPS/EMS/TNT/Shunfeng Express
2Kami bisa memberikan barang ke agen kurir pelanggan kami dan pengiriman dari pabrik ke agen Shenzhen gratis.

T: Bisakah Anda menyediakan layanan kustomisasi atau OEM?

A: 1. Kami dapat menambahkan logo pelanggan pada produk atau paket jika sampel atau desain disediakan.

2Kami dapat menyediakan layanan desain atau manufaktur jika sampel atau desain disediakan.

T: Bisakah kami menjadi distributor Anda di lokal?

A: Ya, kami mencari distributor di setiap negara atau wilayah. Jika Anda tertarik pada distribusi, Anda dapat mengirim email kepada kami secara bebas.

Ingin Tahu lebih detail tentang produk ini
Red Rainbow Tech SpO2 Sensor sekali pakai 1859 2317 LNCS Adtx Rad-57 Radical-7 bisakah Anda mengirimkan saya lebih banyak detail seperti jenis, ukuran, jumlah, bahan, dll.
Terima kasih!
Menunggu jawaban Anda.